Staka TopAccess Roof Access Hatches | Model Overview
Technical specifications
Operation: manual operation with minimal effort needed to open/close due to special gas spring assisted opening with lock function in the open position to prevent accidental closing.
Insulation value of roof access hatch: U= 0.21 W/m2K in compliance with EN-ISO10077-2
Insulation value of insulation material: Rc-value of 7.22 m2K/W
Soundproofing: 23 dB in compliance with EN/ISO10140-1
Wind load: 2400 Pa in compliance with EN 12211
Water tightness: 750 Pa in compliance with EN 12155
Snow load: 950 N/m2 in compliance with EN 1991-1-3
Impact load: 0.35 kNm in compliance with EN 1991-1-1
Upstand height: 330 mm.
Material: stainless steel (AISI 304 or equivalent)
Fitted with cylinder lock with 3-point closure
TÜV certified.
TOP97
Dimensions: 900x700 mm Thermally broken construction Insulation value:U=0.21 W/m2K TÜV certified.